Non Pressure uPVC & Electrical Conduit Pipes  & Fittings

 
 
About

Watertech Non Pressure uPVC & Electrical Conduit Pipes  & Fittings

Watertech Pipes & Fittings Pvt Limited is a key manufacture of uPVC Pressure & Non-Pressure Pipes in KPK Province. Watertech U-PVC (Un-Plasticized Poly vinyl Chloride) Pipes with the brand name of Water-Fit and Crystal-Fit are complete solution for pressure and non-pressure pipes like bore holes, sewerage, electrical conduits and other water supply applications.

Our Crystal-Fit brand is a suitable solution for soil, waste and vent (SWV), underground drain and sewerage applications in homes, commercial buildings, community buildings and large scale infrastructure project.

The Company has state of the art plants and machinery for manufacturing uPVC Pressure pipes according to Pakistan Standard PS 3051-2017 and British Standard BS 3505. Our uPVC Pressure and Non- Pressure sizes range from 2 Inches” upto 10 Inches”.

Usage of Watertech uPVC Pressure and Non-Pressure Pipes

  • Boreholes
  • Pressure mains and potable water distribution networks
  • Drainage installations for sewerage and disposal (both domestic and industrial)
  • Industrial effluent disposal –can be used to transport various types of corrosive liquids with aggressive composition
  • The casing of commercial cables and wires
  • Agriculture, horticulture, and greenhouse irrigation system
  • Chilled water line for refrigeration and air –conditioning system

Non Pressure Pipes

  • BS-3505 CLASS O
  • DIN 19534

Sewerage, Soil, Drain & Ventilation

  • ASTM D-2241SDR Series
  • ASTM D-2665 DWV
  • BS-5255 Thermoplastic Waste Pipe
  • BS4514 Soil and Ventilation
  • BS-4660 & 5481 Underground Sewerage

uPVC Sewerage Pipes

BS 5255 Thermoplastic Waste Pipe

Nominal Size Outer Diameter (mm) Wall Thickness (mm) Thermoplastic Waste Pipe
(Inch) mm Min Max Min Min
1 1/4 32 42.1 42.4 1.8 2.2
1 1/2 40 48.1 48.4 1.9 2.3
2 50 60.2 60.56 2.0 2.4
Nominal Size Outer Diameter (mm) Wall Thickness (mm) Soil & Ventilating Pipes
(Inch) mm Min Max Min Min
2 82 88.7 89.1 3.2 3.8
4 110 114.1 114.5 3.2 3.8
6 160 168.0 168.5 3.2 3.8
Wall Thickness (mm) Underground Sewerage
Nominal Size Outer Diameter (mm) BS 4660 BS 5481
(Inch) mm Min Max Min Max Min Max
4 110 114.1 114.5 3.2 3.8 - -
6 160 168.0 168.5 4.1 4.8 - -
8 200 218 219.4 - - 4.9 5.6
Outer Diameter (mm) Wall Thickness
Nominal Size Average Tolerance on Average Out of Roundness (Max. Minus Min) Minimum Tolerance
1 1/4 1.660(42.16) ±0.005(0.13) 0.240(0.61) 0.140(3.56) + 0.020(0.51)    - 0.000
11/2 1.900(48.26) ±0.006(0.15) 0.240(0.61) 0.145(3.68) + 0.020(0.51)    - 0.000
2 2.375(60.33) ±0.006(0.15) 0.240(0.61) 0.145(3.91) + 0.020(0.51)    - 0.000
3 3.500(88.90) ±0.008(0.20) 0.230(0.76) 0.216(5.49) + 0.026(0.66)    - 0.000
4 4.500(114.30) ±0.009(0.23) 0.100(2.54) 0.237(6.02) + 0.028(0.71)    - 0.000
6 6.625 (168.28 ±0.011(0.28) 0.100(2.54) 0.280(7.11) + 0.34(0.86)    - 0.000
8 8.625(219.08) ±0.015(0.38) 0.150(3.81) 0.322(8.18 + 0.39(0.99)    - 0.000

non pressure uPVC

Mean Outside Diameter (mm)
Nominal Dia Min Max Thickness (mm) Thickness Allowance Weight kg/m
3" 88.7 89.1 1.8 ± .01 0.797
4" 114.1 114.5 1.8 ± .01 1.029
5" 140.0 140.4 2.5 ± .01 2.125
6" 168.0 168.5 3.0 ± .01 2.375
Mean Outside Diameter (mm)
Nominal Dia Min Max Thickness (mm) Thickness Allowance Weight kg/m
1/2" 17.0 17.3 1.04 ± .025 0.086
3/4" 21.0 21.5 1.25 ± .025 0.125
1" 26.6 26.9 1.33 ± .025 1.173
1 1/4" 33.4 33.7 1.51 ± .025 0.245
11/2" 42.1 42.2 1.86 ± .025 0.395
2" 60.2 60.5 2.04 ± .025 0.612
3" 89.7 89.1 1.8 ± .025 0.798
4" 114.1 14.5 1.9 ± .025 1.032